ASME A112.19.13 pdf download

admin
ASME A112.19.13 pdf download

ASME A112.19.13 pdf download.ELECTROHYDRAULIC WATER CLOSETS.
ASME A112.19.13 establishes perfonnance. electricalielecironic conformance, temperature, life cycic. marking. and identification requirements for elcctrohydraulic water closcts,
The use of alternate materials or methods are permitted. provided the proposed material or method complies with the perftnnance requirements and intent of this Standard.
1.2 Units of Measurement
Values are stated in U.S. Customary units and the International System of Units tSl). The U.S. Customary units shall be considered as the standard.
1.3 Reference Standards
The following documents form a part of (his Standard to the extent specitied herein. Unless otherwise indicated, the latest issue shall apply,
ANSI Zl24.4. Plastic Water Closet Bowls and Tanks
Publisher: International Association of Plumbing and Mechanical Officials, 2[X)O I East Walnut Drive South, Walnut, CA 91789
ASME A112.19.2M.Vitreous China Plumbing Fixtures ASMLi Al 12.19.6. Hydraulic Performance Requirements for Water Closets and Urinals
Publisher: The American Society of Mechanical Engineers. ASME Order Department, 22 Law Drive, Box 2300. Fairfield, NJ 07007
UL 62. Flexible Cord and Fixture Wire
UL 157. Gaskets and Seals
UL 244A-l994. Solid-State Controls for Appliances
UL 746C. Polymeric Materials — Used in Electrical Equipment Evaluations
UL 778, Motor Operated Water Pumps
UL 796. Printed-Wiring Boards
UL 817, Cord Sets and Power-Supply Cords
UL 1585. Class 2 and Class 3 Transformers
Publisher: Underwriters Laboratories Inc.. 333 Ptingsten Road. Nonhhrook. IL 60062
2.11 Life Cycle Test
The electrical components and pump shall pass a 75,000 life cycle test. The test shall be performed on the water closet at the maximum cycle rate the electronic controls will allow. Upon completion of the life cycle test, the average volume per flush shall not vary more than 0.15 gal 0.57 lj or 10%. whichever is greater.
3 MARKING AND INSTRUCTION MANUAL
3.1 Marking
3.1.1 Water Closet. The water closet shall be legibly marked as specified in ASME All2.19.2M and other standards referenced in this Standard (see pant. 1.3).
3.1.2 Pump. The pump shall have the following markings visible on it in its nomial operating position and a second label visible on the exterior of the water closet or cord stating:
W ARlING;
The word warning shall be a minimum of ‘12 in. (2.4 mm) high.
3.2 Instruction Manual
An instruction manual shall be provided that includes instructions for routine maintenance and operation.